Videotek VTM-2000 Specifications Page 22

  • Download
  • Add to my manuals
  • Print
  • Page
    / 72
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 21
Operation
VTM-200 Installation and Operation Handbook 3-6
Figure 3-2. Sample SVGA display
Waveform, Vector, and Audio Graticule Scales
Waveform Graticule Scales
The waveform graticule scales change according to the video format being displayed,
as listed in Table 3-2.
Table 3-2. Video Formats and Units of Measure
Video Format Unit of Measure
NTSC composite
IRE
PAL composite
Units or V (selectable)
Digital 525
V
Digital 625
V
Because of the large number of possible front panel control setting combinations, it is
impractical to show every possible screen display. However, the following examples
represent a cross section of what graticules and arrangements of displays can
reasonably be expected.
Figure 3-3 illustrates a full-screen waveform graticule with no signal displayed.
INPUT A has been selected, and the REF is internal. The signal standard is NTSC.
The STATUS is not ON AIR, and the SOURCE ID has been set to read INPUT A.
The SC/H phase is measured to be 0°. The vertical gain is x1, the horizontal time scale
is 5.0 μs per major division, and the FLAT (FL) filter has been selected. The -40 and
+100 IRE scale lines are indicated.
Page view 21