Operation
VTM-200 Installation and Operation Handbook 3-13
Audio Ballistics
The audio display is an option. The audio levels are represented by bar graph level
meters with characteristics selectable to be either IEC Type I, IEC Type IIa, IEC Type
IIb, Type I +8, or Nordic for both analog and digital inputs; for digital inputs only, the
dBfs scale is selectable. The IEC types are according to IEC-268-10 and -17
specifications. The graticules are calibrated in dB, and the selected reference level,
(either 0, +4, +6, +8, or +12 dBm for analog audio inputs, or -22, -20, or -18 dBfs for
digital audio inputs) corresponding to the 0 mark is listed, along with the audio source.
In addition to the L1, R1, L2, and R2 level scales, there are φ1 and φ2 phase
difference scales. φ1 measures the instantaneous phase difference between the
signals applied to the L1 and R1 scales. φ2 measures the instantaneous phase
difference between the signals applied to the L2 and R2 scales. The φ scales are
calibrated in +1 (0°), 0 (90°), and -1 (180°) markings. The region between +1 and 0 is
green; the region between 0 and -1 is red; a yellow indicator mark shows the phase
difference.
The audio scales and ballistics both attack and delay times for meter movement. The
following meter responses can be selected:
NORMAL
PEAK
PEAK HOLD