Alarm Descriptions
VTM Series Installation and Operation Handbook
5-7
Subtitle Not Updating
The Subtitle Not Updating alarm occurs when Subtitles carrier is present and the
subtitles are the same for a period in excess of the duration setting.
WSS (Widescreen Signaling) Not Detected
The Widescreen Signaling Not Detected alarm occurs when the presence of
Widescreen Signaling for Widescreen Format is not detected for a period in excess of
the duration setting.
XDS Not Detected
The XDS Not Detected alarm occurs when the presence of XDS is not detected for a
period in excess of the duration setting.
XDS Not Updating
The XDS Not Updating alarm occurs when XDS is present and the data word is the
same for a period in excess of the duration setting.
Eye Jitter
The Eye Jitter alarm occurs when the eye pattern jitter exceeds the threshold for a
period in excess of the duration setting.
Timing Alarm
The Timing Alarm occurs when the Time and Line range(s) are exceeded for a period
in excess of the duration setting.
Video Alarms Analog Descriptions
The Video Alarms Analog menu contents are listed below.
Loss of Signal
The Loss of Signal alarm occurs when no sync signal is detected for a period in excess
of the duration setting.
Loss of Reference
The Loss of reference alarm occurs when no sync signal is detected in the external
reference for a period in excess of the duration setting. To select the appropriate
external reference see Reference Selection on page 3-48.
Loss of Video
The Loss of Video occurs when active video falls below the adjustable threshold for a
period in excess of the duration setting.