Alarm Descriptions
VTM Series Installation and Operation Handbook
5-9
For example, assume that the Vertical Interval Test Signal of color bars on line 17,
field 2 is selected. Also, assume the line position is set to monitor the blue color packet
with a range of 5° and duration of 0 seconds. If the phase error between burst and the
blue vector point exceeds ± 5°, an alarm occurs.
Horizontal Blanking (H Blanking)
The Horizontal Blanking (H Blanking) alarm occurs when the time interval between
the end of active video and the start of active video violates the specified limits for a
period in excess of the duration setting. The limits are:
NTSC: 10.7 to 11.1µs
PAL: 11.8 to 12.2µs
For this measurement to be accurate, active video must be higher than 20 IRE (NTSC)
or 350 mV (PAL).
Vertical Blanking
The Vertical Blanking alarm occurs if the number of lines during the vertical blanking
period violates the selected width limit for a period in excess of the duration setting.
The selectable widths are 20 Lines to 25 Lines for NTSC and 25 to 30 Lines for PAL.
SC/H Phase
The SC/H Phase alarm occurs when the phase angle of burst compared to the 50%
point of the leading edge of horizontal sync on line 10 of field 1 (NTSC) or line 1
(PAL) exceeds the range setting for a period in excess of the duration setting. The
range is ± 5° to 90° in NTSC and ± 5° to 45° in PAL.
VITS
The VITS alarm occurs when the selected lines become active or inactive as set by the
amplitude threshold for a period in excess of the duration setting. One or more lines
can be monitored, and they do not have to be successive. For example, line 17/E can be
monitored for activity over 50 IRE while line 20/O is monitored for inactivity under 50
IRE. The threshold and duration settings are global.
Captioning
Closed Caption Not Detected - Analog
The Closed Caption Not Detected alarm is activated when the presence of a closed
caption data word on line 21(284) with valid parity bits is not detected in a composite
signal for a period in excess of the duration setting.
Closed Caption Not Updating - Analog
The Closed Caption Not Updating alarm is activated when closed caption carrier is
present and the data word on line 21 is null in a composite signal for a period in excess
of the duration setting.