External Control
VTM Series Installation and Operation Handbook
6-5
Tab/Tab Details
Clicking the Tab at the top of the screen will link to the appropriate tab page, as shown
in the example in Figure 6-1. Table 6-3 describes the fields shown in the Tab/Tab
Details section.
Table 6-3. Tab/Tab Details Description
Key Field Description
1
WEB FUNCTION TABS Click the Tab to access the appropriate Tab page for the
specified tab function.
2
ABOUT The ABOUT tab is a read-only screen that contains the
Firmware Version, VPR ID, Slot 1 ID, Slot 2 ID, Audio ID,
Display firmware version, Panel version, RCU version, and
serial number information. This is similar to the ABOUT
screen described on page 4-49.
3
GPIO The GPIO tab displays the GPI Alarm Rename screen. All 9
GPI Alarm names can be changed on this screen. There is a
16-character limit for each GPI Alarm Name. This screen is
similar to the section on GPI Input Function and GPI Alarm
Names on page 4-42.
4
SYSTEM The System Screen is used to rename the Input Source IDs
and indicate the number of current monitored alarms. The
Input Source ID is described on page 4-31.
The number of current monitored alarms field is a read-only
display that indicates the number of active alarms for the
selected input. This field does not indicate the alarms for all
the inputs at the same time.
5
TIMECODE ALARMS The Time Code Alarms Screen indicates the Alarm Enable
and Parameter Settings field for each Time Code Alarm. The
Enable Field is set with a “0” for Disable Alarm or a “1” for
Enable Alarm. See Table 4-10 on page 4-21 for the list of
alarm parameters.
6
ANALOG ALARMS The Analog Alarms Screen indicates the Alarm Enable and
Parameter Settings field for each Analog Video Alarm. The
Enable Field is set with a “0” for Disable Alarm or a “1” for
Enable Alarm. See Table 4-9 on page 4-15 for the list of
alarm parameters.
7
DIGITAL ALARMS The Analog Alarms Screen indicates the Alarm Enable and
Parameter Settings field for each Digital Video Alarm. The
Enable Field is set with a “0” for Disable Alarm or a “1” for
Enable Alarm. See Table 4-8 on page 4-10 for the list of
alarm parameters.
8
AUDIO ALARMS The Audio Alarms Screen indicates the Alarm Enable and
Parameter Settings field for each Audio Alarm. The Enable
Field is set with a “0” for Disable Alarm or a “1” for Enable
Alarm. See the A
3
-OPT 3, A
3
-OPT 4, A
3
-OPT 5, and A
3
-4004
Installation and Operation Handbook for the complete list of
audio alarms for the selected option.
9
TAB PAGE Lists all the fields associated with the selected tab. To see the
latest values of the instrument for the selected TAB PAGE
press the F5 button to refresh the screen.
(Table continues on next page)