Global Setup Menu Functions
VTM-2000 Installation and Operation Handbook
4-14
Ref Level Digital
The Ref Level Digital setting is used to set the reference level on the meters for a
digital signal. Content below this setting is green. Content above this setting is
yellow.
Peak Program Level Analog and Digital
Analog and Digital Peak Program Level is a range set for each scale type that shows
red when the audio level exceeds this range. The range starts at the set reference level
and changes in 1 dB increments.
Analog and Digital Scales
The Analog and Digital Scales submenus are used to determine the type of scale that
appears on the audio meter display.
Meter Response
Ballistics specifications are shown in Table 4-14. These specifications describe meter
scale markings and both attack and decay times for meter movement.
Table 4-14. Ballistic Specifications with Attack and Decay
Ballistic Name Standard Attack Decay
VU
IEC 268-17 300 ms 300 ms
PEAK
IEC 268-10 10 ms 1.7 sec
TRUE PEAK
IEC 268-10 0 ms 1.7 sec
The audio scales and ballistics are based on the IEC 268-10 and IEC 268-17 standards.
These standards describe meter scale markings and both attack and decay times for
meter movement.
The following meter responses can be selected:
VU (NORMAL)
PEAK
TRUE PEAK
VU + PEAK
VU + TRUE PEAK
PK (Peak) Hold
PK (PEAK) HOLD TIME is a user-selectable duration value of OFF, 1 to 10 seconds,
or infinite. The duration only applies to the hold time of the PEAK value, not the
attack or decay time. RESET PEAK manually resets the Peak value.