Global Setup Menu Functions
VTM-2000 Installation and Operation Handbook
4-17
Screen Saver
The screen saver is used to provide a blank screen after there is no activity for the
specified duration. The time it takes for the screen saver to activate can range from 1
to 60 minutes. OFF disables the screen saver. When the screen saver is activated,
press any button to turn the display back on.
Output Level
The Output Level submenu is used to determine the monitor output level. The default
monitor output level is 1V p-p. The other output level selection is 0.7V p-p.
Time Code
Time Code is used to display the Time Code on the right side of the picture. The Time
Code can be displayed on the Top-right, Middle-right, or Bottom-right side of the
picture.
Communications Setup
The Communications Setup menu is used to configure the communication between the
VTM-2000 and any peripheral hardware and Software connected to the unit.
RCU Port
The RCU Port submenu controls the termination for the Remote Port on the back of the
VTM-2000.
Termination
One RCU-2000 connects to multiple VTM-2000 instruments using a multidrop straight
through wire with RJ-11 connectors (not a standard telephone wire) that connects to the
REMOTE ports on the back of the VTMs and to the TO MAIN UNIT connector on the
back of the RCU. All VTMs must have unique unit IDs, as described in Unit ID on
page 4-19. The REMOTE port must be terminated on the last VTM-2000 using this
menu.
IP Configuration
The IP CONFIGURATION menu is used to configure the VTM-2000 for Ethernet
communication. The Ethernet interface provides a high-speed communication link to
the VFlash application over standard LAN and Internet networks. The interface
conforms to industry Ethernet standards:
Connection via a standard RJ45 socket
Automatic detection and switching between 10BaseT and 100BaseT
TCP/IP stack is fully compliant with RFC2500, “Internet Official Protocol
Standards”
Fully compliant with the IEEE 802.3 Ethernet standard
The interface can accept a static IP address, or it can obtain an IP address dynamically
from a DHCP server. The IP Address, Subnet Mask, Gateway Address, and DHCP are