Section 6 Troubleshooting
CAUTION — these instructions are for use by qualified personnel only. To reduce
the risk of electric shock, do not perform this installation or any servicing unless you
are qualified to do so. Refer all servicing to qualified service personnel.
NOTE: When power is applied to the unit, the display shows the startup screen for about 25 seconds.
If the VTM-2000 is not functioning properly, first verify that:
The VTM-2000 is connected to a power source (90–264 VAC, 50/60 Hz nominal).
All cables are correctly connected (see Section 2, “Installation”).
Initial difficulties with operation or display can be due to improper setup. Review the
operation was correct to ensure that the proper adjustments have been made for the
signal requirements.
Cold Starting the VTM-2000
NOTE: A cold start resets all front panel and Setup menu selections to the factory-default settings. All
user settings are lost.
If a problem persists after the cables are correctly connected and the unit is set up,
perform a Cold Start. Three procedures can cold start the VTM-2000. Only one
procedure needs to be performed to cold start the unit. The first type of cold start
procedure is a front panel Cold Start, as described below. The second type of cold start
procedure is a Warm Start that is described on page 7-2. The third type of cold start is
a Cold Start after a VFlash update that is described on page 7-2.
The Ethernet default settings for the VTM-2000 are:
IP: 192.0.0.100
Subnet Mask: 255.255.255.192
Gateway: 0.0.0.0
Cold Start
The Front Panel Cold Start procedure is a cold starting procedure that does not require
the power to be disconnected from the unit. To perform a Front Panel Cold Start:
1. Push and hold the EXIT button, PRESET button, and DOWN button. For a
minimum of five seconds. The Cold Start message appears on the screen.
2. Once the message appears, the cold start is complete.