Videotek VTM-2000 Specifications Page 99

  • Download
  • Add to my manuals
  • Print
  • Page
    / 116
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 98
RCU-2000 Remote Control Unit
VTM-2000 Installation and Operation Handbook
C-3
9. The VTM-2000 polls the selected RCU-2000 every five seconds. If the VTM-2000
instrument fails to receive the poll after 60 seconds, the RCU-2000 assumes that a
communication break has occurred.
The LEDs flashing indicates a communication break. When communication is
once again established, the LEDs will reflect the current setting.
Operating the RCU-2000
Operating the RCU-2000 is the same as operating a VTM-2000 instrument with one
exception: selecting a VTM-2000 instrument for communication.
To select a VTM-2000 instrument for communication:
1. Press and hold the SETUP and EXIT buttons simultaneously to enable the selection
mode. The Phase LEDs flashes.
2. Rotate the CURVED ARROW knob to search for a Unit ID. Rotating clockwise
scans UP through the UNIT IDs. Rotating counterclockwise scans down through
the unit IDs.
Troubleshooting
Table C-2. RCU-2000: Problems, Causes, and Solutions
Problem/Symptom Possible Cause Solution or Explanation
The DC power supply cable is not
properly connected to the back panel
5V DC IN connector.
Properly connect the DC power
supply.
The LEDs are not
illuminated.
The DC power supply has no AC power
applied.
Apply the AC power.
The RJ-11 cable from the VTM-2000
instrument to the RCU-2000 is
defective or not properly connected.
Check the cable and the
connection.
VTM-2000 instrument not powered up. Apply the power to the VTM-2000
instrument.
Bottom Row LEDs are
flashing.
A VTM-2000 instrument is not selected. Select a VTM-2000 instrument.
If the problem still exists after troubleshooting the RCU-2000, see Section 1, “Service
Support,” for further instructions.